Customization: | Available |
---|---|
After-sales Service: | One Year or 1200 Hour |
Warranty: | One Year or 1200 Hour |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ZHONG SHAN CHUANGYUAN POWER EQUIPMENT.,LTD | ||
Industrial generator set technical Sheet | ||
Genset Model | CYGF-CK90-50P-S | |
Genset Output(Kw/Kva) | 90/112.5 | |
Rated speed (r/min) | 1500 | |
Rated Voltage(V) | 400 | |
Rated frequency(Hz) | 50 | |
Ranted current(A) | 162.4 | |
Power factor( Cos φ) | 0.8(lagging) | |
Number of phase/Lines | Three phase four wire | |
Controller brand | SmartGen | |
Switch brand | CHINT | |
Battery | 2*120Ah | |
Industrial silencer with flexible connects | YES | |
Fuel tank | YES | |
Test report, Drawing , Manuals | YES | |
Silent Genset weight(kg) | ≈2.5T | |
Silent Genset size(LxWxH)mm | ≈3200*1100*1750 | |
Engine | Model | 6BTA5.9-G2 |
Type | Four stroke, in-line, water cooling, pressurized air cooling | |
Prime Output(kW) | 104 | |
standby output(kW) | 116 | |
Cylinder/Bore/Stroke | 6/102/120 | |
Displacement(L) | 5.9 | |
Compression ratio | 17.3:1 | |
Oil capacity(L) | 16.4 | |
Coolant capacity(L) | 11 | |
Speed regulation mode | Electrical governor | |
Starting mode | DC24V electric start(Battery) | |
Cooling mode: | Closed fresh water circulating cooling | |
Firing sequence(From the free end) | 1-3-4-2 | |
Crankshaft rotation direction | Counter clockwise(facing flywheel end) | |
Place of Origin | CCEC | |
Alternator | Model | KAL274B2 |
Rated capacity(KVA) | 112.5 | |
Rated output(kW) | 90 | |
Rated voltage(V) | 400 | |
Rated current(A) | 162.4 | |
Rated frequency(Hz) | 50 | |
power factor( Cos φ) | 0.8(lagging) | |
Protection level: | IP23 | |
Insulation grade | H | |
Excitation mode | Brushless AVR,excitation | |
Phase number | Three phase four wire | |
Place of origin | Kwise Generator Pte Ltd | |
Function | Power supply form | Battery 24V power supply |
show contents |
Voltage, current, frequency, KVA, kW, kvar, kwh, KVAh, kvarh, power factor PF, mains voltage, mains frequency, speed, oil pressure, cooling water temperature, unit operation time, battery voltage, etc | |
Safety protection function |
Overspeed alarm, overspeed high shutdown, low oil pressure alarm, low oil pressure shutdown, high water temperature alarm, high water temperature shutdown, overvoltage alarm (120%) shutdown, undervoltage alarm (85%) shutdown, overcurrent alarm (110%) shutdown, low battery voltage (< 19v) alarm |